PELRINE & BUCHANAN'S MARITIME TRADING WORLDWIDE LTD.



Three (3) 50 MW Coal Fired Steam Turbines, total 150 MW

62.5 MVA
10.5 KV
3000 rpm
50HZ
Year 1994 and 1995
Boiler type single steam natural convection coal dust boiler.
Contact us for information
 

pictures

 

Generator


Model: QFQ-50-2-B
Output: 62.5 MVA
Stator current: 2440A
Stator voltage: 10.5kV
Frequency: 50 Hz
Speed: 3000 rpm
Cooling: hydrogen external cooled
Insulation: class B

Steam Turbine


Model: N50-8.83-1 high pressure, single cylinder, condensing type
Rated power: 50MW
Max power: 55MW (only under certain condition, not for testing)
Speed: 3000 rpm
Steam inlet pressure: 8.83Mpa
Steam inlet temp: 535 ゚C
Low pressure steam exhaust pressure: 0.0054Mpa (at meter 0.1013-0.0054=0.0959Mpa)
Exhaust temp at load max 65゚C
Cooling water temp: normal 20゚C, max 33゚C
Cooling water flow: 8160T/h
Water inlet temp: 220゚C
Total 21 stage (1 adjustable +20 pressure stages), at stage 5,8,11,15,17,19 set non-adjustable steam extraction. At the 5th stage of the steam turbine bottom, there are 2 nos of Ø168 adjustable heat extraction holes, pressure: 1.4Mpa to 2.69Mpa, temp: 337.8 to 400.4゚C
Steam turbine with heating system has total steam consumption rate: 193.032t/h, steam consumption
( guarantee value): 3.72kg/kwh, heat rate : 9399kj/kwh

  unit Adjustable stages First section Second section Third section Fourth section Fifth section Sixth section
Extraction point   Back of stage 1 Back of stage 5 Back of stage 8 Back of stage 11 Back of stage 15 Back of stage 17 Back of stage 19
Extraction steam pressure Mpa 5.6 2.691 1.385  0.772 0.293 0.131 0.041
Extraction temp ゚C 480 390 312 249 156 107 76
Extraction capacity T/h   12.28 6.83  8.21 6.36 8.85 6.9
Re-heater output temp ゚C    220.4 190 158 130  105 75
 Re-heater     #2 high add #1 high add De-oxygenetor #3 low  add  #2 low add  #1 low add

Boiler


Boiler type single steam natural convection coal dust boiler, steel structure, reverse U layout.
Model: SG-220/9.8-M298
Date of operation: #3 April 1994, #4 Oct. 1994, #5 Aug. 1995
Maker: Shanghai Boiler Factory
Rated capacity: 220t/h
Saturated steam pressure: 10.78Mpa
Overheat Steam pressure: 9.8Mpa
Steam temp: 540゚C
Boiler efficiency: 91.1%

Last major overhaul of power plant:


Turbine #3 Feb, 2004
Turbine #4 Dec, 2007
Turbine #5 Feb, 2005

Valid XHTML 1.0 Transitional